+441225535040

Mon-Fri: 8:00 - 18:00 UK

Email:

Advantages

Only the best I&C brands

Our company is a global supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at very low prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Europe & Asia

We take care of all logistics and customs clearance of I&C solutions from Europe, USA, China and India

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Device selection filter

Device selection filter

SF6 Gas Density Monitor

Our company offers you to buy SF6 Gas Density Monitor at excellent prices. Leave a request on the website and our specialists will send you a quotation within 1-2 days.

Products not found

Case diameter – 100mm. Scale range from -0.1 to 0.9 MPa (adjustable). Accuracy (depends on measuring range; SF6 in gas phase) – at 20°C: class 1.0, 1.5 and -40°C to +60°C: class 2.5. Degree of protection – IP65. Ambient conditions – -40°C to +60°C, relative humidity ≤95%RH. Leakage rate – ≤ 1 × 10-9 Pa-m3/s (helium leakage monitoring). Connection method – radial or axial. Contact type – snap-action magnetic switch with 80%Ag, 20%Ni, 10 µm Au coating. Output signal – RS485. Protocol – ModBus RTU.

price by request

Read more
Available

Available

Measuring range – 0 to 1.0 MPa abs. or 0 to 0.2 MPa abs. (adjustable). Accuracy – at 20°C: class 1.0 and -40°C to +60°C: class 2.0. Degree of protection – IP65. Ambient conditions – -40°C to +60°C, relative humidity ≤95%RH. Leakage rate – ≤ 1 × 10-9 Pa*m3/s (helium leakage monitoring). Output signal – RS485. Protocol – ModBus RTU.

price by request

Read more
Available

Available

Scale range: -0.1 to 0.9MPa (customizable), Set point Accuracy: +20±1℃,±1.0%FS,-30~+60 ℃,±1.5%FS(gas phase; Indication accuracy:rated pressure:+20±1℃,±1.0%FS, -20~+60 ℃,±1.8%FS(gas phase),-30~-20 ℃,±2.3%FS(gas phase); Degree of protection: IP65; Ambient conditions: -40°C to 60°C; Leakage rate:< 1 × 10-9 Pa·m3/s , Relative humidity ≤ 95%RH; Pressure connection: M20 × 1.5, (customizable); Electrical connection: Connect the plug when plugging, wire diameter 0.2…2.5 mm2; Insulation properties:Insulation resistance: >100 MW (500 V DC), Withstand voltage: 2kV, 50/60 Hz 1 min (to case); Contact ratings: 10(1.5)A,250V AC, 0.1 (0.05)A,250V DC;

 

price by request

Read more
Available

Available

Ambient conditions from -40°C to +80°C. Output signal – RS485. Protocol – ModBus RTU. Pressure/temperature/dew point range – 0~1.4MPa abs./-40℃~+80℃/-50℃~+20℃. The accuracy of pressure/temperature/dew point measurement is ±0.5% FS/ ±0.5℃/±3℃. Leakage rate – ≤1X10-9Pa-m3/s. Protection degree – IP65. Output signal – RS485. Protocol – ModBus RTU.

price by request

Read more
Available

Available

Scale range -0.1 to 0.9 MPa (customizable). Set point Accuracy: -30~+50 °C, ±1.0%FS (±10KPa) (gas phase). Degree of protection – IP65. Ambient conditions from -40°C to +60°C. Leakage rate – < 1 × 10-9 Pa-m3/s, relative humidity ≤ 95%RH. Contact type – microswitch.

price by request

Read more
Available

Available

Case diameter – 100mm. Measuring range – -0.1 to 0.9 MPa (adjustable). Accuracy (depends on measuring range; SF6 in gas phase) – at 20°C: class 1.0, 1.5 and -40°C to +60°C: class 2.5. Degree of protection – IP65. Ambient conditions from -40°C to +60°C, relative humidity ≤95%RH. Connection method – radial or axial. Contact type – snap-action magnetic switch with 80%Ag, 20%Ni, 10 µm Au coating.

price by request

Read more
Available

Available

Scale range from -0.1 to 0.9 MPa (customizable). Set point accuracy from -30~+50 °C, ±1.0%FS (±10KPa) (gas phase). Degree of protection – IP65. Ambient conditions from -40°C to +60°C. Leakage rate – < 1 × 10-9 Pa-m3/s, relative humidity ≤ 95%RH. Contact type – microswitch. Output signal – RS485 and fibre optic. Protocol – ModBus RTU.

price by request

Read more
Available

Available

Scale range from -0.1 to 0.9 MPa (adjustable). Accuracy – ±10 kPa ( -30 to +50 °C. Degree of protection – IP65. Ambient conditions from -40°C to +60°C, relative humidity ≤95%RH. Leakage rate – ≤1×10-9 Pa-m3/s (helium leakage monitoring). The connection method is radial or axial. The contact type is microswitch.

price by request

Read more
Available

Available

Case diameter – Φ64 mm. Scale range – 1.0 to 2 bar abs. Accuracy – at 20°C: 1.0 or 1.5 and -40°C to +60°C: class 2.5. Degree of protection – IP65. Ambient conditions from -40°C to +60°C, relative humidity ≤95%RH. Connection method – radial or axial. Contact type – magnetic latching switch (maximum two groups, normally open or normally closed, customizable to 3 groups according to user needs). Output signal – RS485. Protocol – ModBus RTU.

price by request

Read more
Available

Available

Case diameter- 100mm. Scale range from -0.1 to 0.9 MPa (adjustable). Accuracy (depends on measuring range; SF6 in gas phase) – at 20°C: class 1.0, 1.5 and -40°C to +60°C: class 2.5. Degree of protection – IP65. Ambient conditions from -40°C to +60°C, relative humidity ≤95%RH. Leakage rate – ≤ 1 × 10-9 Pa-m3/s (helium leakage monitoring). Connection method – radial or axial. Contact type – snap-action magnetic switch with 80%Ag, 20%Ni, 10 µm Au coating. Output signal – RS485. Protocol – ModBus RTU.

price by request

Read more
Available

Available

Body diameter – 50 mm. Measuring range – 0 to 6 bar. Accuracy – Class 1.0 or 1.5 at 20°C; Class 2.5 at -30°C to + 60°C; Class 3.0 at -40°C to – 30°C. Ambient conditions – -40°C to +60°C. Weight – 0.2 kg.

price by request

Read more
Available

Available

Case diameter – 100mm. Scale range from -0.1 to 0.9 MPa (adjustable). Accuracy (depends on measuring range; SF6 in gas phase) – at 20°C: class 1.0, 1.5 and -40°C to +60°C: class 2.5. Degree of protection – IP65. Ambient conditions – -40°C to +60°C, relative humidity ≤95%RH. Leakage rate – ≤ 1 × 10-9 Pa-m3/s (helium leakage monitoring). Connection method – radial or axial. Contact type – snap-action magnetic switch with 80%Ag, 20%Ni, 10 µm Au coating. Output signal – RS485 and fibre optic. Protocol – ModBus RTU.

price by request

Read more
Available

Available

Case diameter – 64 mm. Scale range – 0 to 2 bar abs. Accuracy – Class 1.0 or 1.5 at 20°C; Class 2.5 at -30°C to + 60°C; Class 3.0 at -40°C to – 30°C.Degree of protection – IP65. Ambient conditions – -40°C to +60°C. Weight – 0.3 kg.

price by request

Read more
Available

Available

Case diameter – 100mm. Scale range from -0.1 to 0.9 MPa (adjustable). Accuracy (depends on measuring range; SF6 in gas phase) – at 20°C: class 1.0, 1.5 and -40°C to +60°C: class 2.5. Degree of protection – IP65. Ambient conditions from -40°C to +60°C, relative humidity ≤95%RH. Leakage rate – ≤ 1 × 10-9 Pa-m3/s (helium leakage monitoring). Connection method – radial or axial. Contact type – snap-action magnetic switch with 80%Ag, 20%Ni, 10 µm Au coating. Output signal – fibre optic. Protocol – ModBus RTU.

price by request

Read more
Available

Available

Scale range – 0 to 3 bar. Accuracy – ±2.0% (-30 °C to +50 °C ). Degree of protection – IP42. Ambient conditions – -30°C to 60°C, relative humidity ≤95%. Leakage rate – ≤ 1 × 10-9 Pa*m3/s. Connection method – axial. Contact type – microswitch.

price by request

Read more
Available

Available

Case diameter – 100mm. Scale range from -0.1 to 0.9 MPa (adjustable). Accuracy – at 20°C: class 1.0, 1.5 and -40°C to +60°C: class 2.5. Degree of protection – IP65. Ambient conditions – -40°C to +60°C, relative humidity ≤95%RH. Leakage rate – ≤ 1 × 10-9 Pa-m3/s (helium leakage monitoring). Connection method – radial or axial. Contact type – magnetic switch with latches and 80%Ag, 20%Ni, 10 µm Au coating. Output signal – wireless. Protocol – ModBus.

price by request

Read more
Available

Available

Scale range: 0 to 1.0MPa abs. (customizable), Accuracy: (related to the measuring span; SF6 in gas phase) a) At 20°C: Class 1.0, b) -40°C to +60°C: Class 2.5, Degree of protection: IP65, Ambient conditions: -40°C to +60°C, relative humidity ≤ 95%RH, Leakage rate: ≤1 × 10-9 Pa·m3/s (Helium leakage inspection), Electrical connection: Seven-core aviation plug, passing EMI test

price by request

Read more
Available

Available

Case diameter – Φ64 mm. Scale range from 0 to 2 bar (abs.) or -1 to 6 bar. Accuracy – at 20°C: 1.5 and -40°C to +60°C: class 2.5. Degree of protection – IP65. Ambient conditions – -40°C to +60°C, relative humidity ≤95%RH. Connection method – radial or axial. Contact type – magnetic latching switch (maximum two groups, normally open or normally closed, configurable to 3 groups according to user needs).

price by request

Read more
Available

Available

GDOMS online gas density monitoring system is a small interval monitoring system or station as one unit, compact and economical, displaying real time temperature, pressure, density value in SF6 chambers inside the system compactly and economically.

price by request

Read more
Available

Available

Case diameter – Φ64 mm. Scale range from 0 to 2 bar (abs.) or -1 to 6 bar. Accuracy – at 20°C: 1.5 and -40°C to +60°C: class 2.5. Degree of protection – IP65. Ambient conditions – -40°C to +60°C, relative humidity ≤95%RH. Connection method – radial or axial. Contact type – magnetic latching switch (maximum two groups, normally open or normally closed, customisable to 3 groups according to user needs). Output signal – RS485. Protocol – ModBus RTU.

price by request

Read more
Available

Available

Gas concentration alarm range of SF6 – 50 ~ 2000PPM (alarm point can be customized, norm 1000PPM). Oxygen measurement accuracy – <0.4%. Communication - standard RS485 protocol

price by request

Read more
Available

Available

Case diameter – Φ64 mm. Measuring range – 1.0 to 2bar abs. Accuracy – at 20°C: class 1.0, 1.5 and -30°C to +60°C: class 2.5. Degree of protection – IP65. Ambient conditions – -30°C to +60°C, relative humidity ≤95%RH. Leakage rate – ≤ 1 × 10-9 Pa-m3/s (helium leakage monitoring). Connection method – radial or axial. Contact type – electronic magnetic signalling contact. Output signal – RS485.

price by request

Read more
Available

Available

Range – pressure calibration range is 0~1Mpa; temperature is -40℃~+125℃. Accuracy – 0.20%. Resolution – pressure display resolution 0.001Mpa; temperature display resolution 0.1℃

price by request

Read more
Available

Available

Case diameter – Φ64 mm. Scale range – 0 to 2 bar (abs.) or -1 to 6 bar. Accuracy – at 20°C: 1.5 and -40°C to +60°C: class 2.5. Degree of protection – IP65. Ambient conditions from -40°C to +60°C, relative humidity ≤95%RH. Connection method – radial or axial. Contact type – magnetic latching switch (maximum two groups, normally open or normally closed, configurable to 3 groups according to user needs).

price by request

Read more
Available

Available