SIKA TP3M165E.2 Multi-function temperature calibrator

  • Patented control technology – time saving up to 50 %
  • Four functions in one calibrator (dry block / calibration bath / infrared / surface)
  • Large calibration volume for simultaneous calibration of many DUT
  • Fastest stabilisation times on the market
			
Warning: Undefined variable $term_list in /home/users/o/olil/domains/dolcetrade.com/wp-content/themes/olil2/template-parts/post/content-listing-with-gallery.php on line 76
int(10135) NULL

Made in Germany. brand SIKA, model TP3M165E.2

International delivery to Europe, Asia and Africa.
Our warehouses are located in the UK, UAE and Senegal.

price by request

Available

Available

Advantages

Only the best I&C brands

Our company is a global supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at very low prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Europe & Asia

We take care of all logistics and customs clearance of I&C solutions from Europe, USA, China and India

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Description of SIKA TP3M165E.2

Whether for on-site use in the workshop, in the measuring and test room or laboratory, SIKA temperature calibrators can be used everywhere. A wide range of industries and various application areas are covered.

• assembly, commissioning

• manufacturing, production

• maintenance, service

• quality assurance, test equipment monitoring

• repair

Calibration bath function

If temperature sensors with unusual shapes and dimensions are to be checked, the use of calibration liquids offers advantages. The DUT is placed directly into the liquid without insulating air gaps, thus creating a direct temperature seal between the calibrator and the DUT. The liquid, e.g. silicone oil, is selected according to the required calibration temperature. The continuously variable control of the magnetic stirrer, together with the pull-out sensor basket, causes vortices in the calibration liquid and thus creates a large homogenous temperature zone. Furthermore, the sensor basket ensures an unobstructed stirring operation and serves to protect the tank bottom.

Dry block function

The dry block function was developed to enable easy calibration of the temperature in lab and field applications. The optimum thermal coupling from block to DUT is achieved by the correct calibration insert. Ideally, the inner diameter of the bore hole in the calibration insert is 0.5 mm larger than the outer diameter of the DUT. With the help of the calibration insert almost all straight temperature sensors with different lengths and diameters can be calibrated. The dry block covers the entire temperature range without changing the calibration medium. The user does not have to take viscosities, flash points or outgassing into consideration.

Dark-radiation function

A patented infrared calibration insert is used to calibrate IR pyrometers or thermal imaging cameras. The special surface structure and the asymmetrical shapes form a “black cavity radiator” with an emission factor of 0.9994 and prevent the reflection of interfering radiation and emit the desired temperature in an ideal form. The pyrometer is simply held at the prescribed distance above the measuring port and thus forms the desired measuring spot for the calibration to be carried out on the ground. The direct mounting of a tripod is possible.

Surface temperature function

Surface temperature sensors are calibrated by means of special calibration inserts which are placed vertically with the required contact pressure. The best possible temperature reference point on the surface of the calibration insert is found by switching the calibrator control to the external reference temperature sensor. This is located directly under the front face of the calibration insert. The calibration insert is designed in such a way that the best temperature homogeneity is achieved in the middle of the front face. A good thermal contact is enabled by the special surface structure of the front face. The use of heat-conducting paste or other heat transfer media is not necessary.

Accessories

The extensive range of accessories for the TP Premium series enables time-saving calibration setups. For example, DUT can be identified via barcode scanner or an ongoing or already completed calibration process can be displayed via WLAN connection on a PC or smartphone anywhere in the world. Thanks to the possibility of connecting an external measuring bridge directly to the calibrators, many DUT can be calibrated at the same time – including automatic generation of individual SIKA works calibration certificates.

Technical specifications of SIKA TP3M165E.2

TP 3M165E.2 / TP 3M165E.2i
  -35…165 °C at ambient temperature 20 °C -31…329 °F at ambient temperature 68 °F
Temperature range See the respective calibration function for details.
Dimension for the calibration insert Ø 60 x 170 mm (calibration insert easily exchangeable)
Dry block Air Shield Insert Temperature range:

-30…160 °C (-22…320 °F)

External reference temperature sensor
Display accuracy ±0.07 °C ±0.126 °F
Temperature stability ±<0.001…0.005 °C ±0.0018…0.009 °F
Temperature distribution

g Axial

g Radial

±0.060 °C

±0.010 °C

±0.108 °F

±0.018 °F

Influence of load ±0.010 °C ±0.018 °F
Dry block

Temperature range:

-30…165 °C (-22…329 °F)

External reference temperature sensor                         Internal reference temperature sensor
Display accuracy ±0.10 °C ±0.18 °F ±0.27 °C ±0.486 °F
Temperature stability ±0.005 °C ±0.009 °F ±0.010 °C ±0.018 °F
Temperature distribution

g Axial

g Radial

±0.200 °C

±0.050 °C

±0.36 °F

±0.09 °F

±0.200 °C

±0.050 °C

±0.36 °F

±0.09 °F

Influence of load ±0.080 °C ±0.144 °F ±0.150 °C ±0.27 °F
Calibration bath (stirred), direct filling Temperature range:

-35…155 °C (-31…311 °F)

External reference temperature sensor                         Internal reference temperature sensor
Display accuracy ±0.19 °C ±0.342 °F ±0.24 °C ±0.432 °F
Temperature stability ±0.010 °C ±0.018 °F ±0.020 °C ±0.036 °F
Temperature distribution

g Axial

g Radial

±0.325 °C

±0.080 °C

±0.585 °F

±0.144 °F

±0.325 °C

±0.080 °C

±0.585 °F

±0.144 °F

Influence of load ±0.040 °C ±0.072 °F ±0.200 °C ±0.36 °F
Calibration bath (stirred), tub insert Temperature range:

-35…155 °C (-31…311 °F)

External reference temperature sensor                         Internal reference temperature sensor
Display accuracy ±0.20 °C ±0.36 °F ±0.28 °C ±0.504 °F
Temperature stability ±0.010 °C ±0.018 °F ±0.020 °C ±0.036 °F
Temperature distribution

g Axial

g Radial

±0.350 °C

±0.080 °C

±0.630 °F

±0.144 °F

±0.350 °C

±0.080 °C

±0.630 °F

±0.144 °F

Influence of load ±0.040 °C ±0.072 °F ±0.300 °C ±0.54 °F
Infrared calibration Temperature range:

-35…165°C (-31…329 °F)

External reference temperature sensor                         Internal reference temperature sensor
Display accuracy ±0.5 °C ±0.9 °F ±0.5 °C ±0.9 °F
Temperature stability ±0.020 °C ±0.036 °F ±0.020 °C ±0.036 °F
Emission factor 0.9994
Surface calibration Temperature range:

-25…150°C (-13…302 °F)

External reference temperature sensor
Display accuracy ±1 °C ±1.8 °F
Temperature stability ±0.150 °C ±0.27 °F
TP 3M165E.2 / TP 3M165E.2i
Stabilisation time

(with external reference temperature sensor)

 
g to ±0.05°C

g to ±0.005°C

g to ±0.09 °F

g to ±0.009 °F

From 1 min

From 5 min

Heating time  
g 20 °C…155 °C

g -35 °C…155 °C

g 68…311 °F

g -31…311 °F

27 min

34 min

Cooling time  
g 165 °C…30 °C

g 20 °C…-25 °C

g 329…86 °F

g 68…-13 °F

17 min

35 min

Resolution of the temperature display 0.001 °C 0.001 °F
Hysteresis ±0.010 °C ±0.018 °F
Temperature units °C / °F / K (selectable)
Reference temperature sensor internal, fixed installation / external (selectable)
Interfaces Ethernet, 3 x USB
Connectivity OPC UA, HTTP. Details and further possibilities on request.
Dimensions  
g Width

g Height

g Depth

210 mm

380 + 50 mm (Handle)

300 mm

Weight Approx. 13 kg
Power supply 100…240 VAC, 50 / 60 Hz
Power consumption Approx. 375 W
Adjustable temperature range -50…165 °C -58…329 °F
Display Brilliant color touchscreen (7 inches), multi panel safety glass

User Guide and Instruction manual for SIKA TP3M165E.2

You can request the necessary certificates, documentation, instructions and user manuals for SIKA TP3M165E.2 using the special form.

You can buy SIKA TP3M165E.2 in UK or Europe at a favourable price in «DOLCHETRADE» by leaving a request on the website, by phone +441225535040 or by email . SIKA TP3M165E.2 price are subject to change depending on exchange rates. We deliver instruments by transport companies in the United Kingdom and Europe.