+441225535040

Mon-Fri: 8:00 - 18:00 UK

Email:

GEORGIN FKE Level transmitter

  • SMART Transmitter: 4-20mA + HART protocol
  • Span limit : from 10 to 300.000 mmWC
  • Rangeability : 100:1
  • Accuracy: 0.165% (0.1% as an option)
  • Power supply 10.5 to 45VDC
  • Process wetted parts material avec le fluide en 316L st. st., Hastelloy, Monel, Tantalum,
  • Process connection by flange
  • Burnout according NAMUR NE43 recommandations
  • Long term stability: +/- 0.1% of maximum span / 10years

Options:  Local analog or digital indicator, Intrinsically safe version, Explosion proof version, FM, CSA and IECEx certification, Stainless Steel electronic housing

			
Warning: Undefined variable $term_list in /home/users/o/olil/domains/dolcetrade.com/wp-content/themes/olil2/template-parts/post/content-listing-with-gallery.php on line 76
int(7698) NULL

Made in France. brand GEORGIN, model FKE

International delivery to Europe, Asia and Africa.
Our warehouses are located in the UK, UAE and Senegal.

price by request

Available

Available

Advantages

Only the best I&C brands

Our company is a global supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at very low prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Europe & Asia

We take care of all logistics and customs clearance of I&C solutions from Europe, USA, China and India

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Description of GEORGIN FKE

The ProcessX level transmitter accurately measures liquid level and transmits a proportional 4 to 20 mA signal.
The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality.

FEATURES

High accuracy:
0.165% accuracy for all calibrated spans is a standard feature. The micro-capacitance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment. 0.1% accuracy is available as option.

Minimum inventory and design:
Electronics unit, local indicators and electronics housing are interchageable among all ProcessX transmitters.

Minimum environmental influence:
The “Advanced Floating Cell” design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual field applications.

Georgin/HART® bilingual communications protocol:
ProcessX series transmitter offers bilingual communications to speak both Georgin proprietary protocol and HART®. Any HART® compatible devices can communicate with ProcessX.

Application flexibility:
Various options that render the ProcessX suitable for almost any process applications include :

  • Full range of hazardous area approvals,
  • Built-in RFI filter and lightning arrester,
  • 5-digit LCD meter with engineering unit,
  • Stainless steel electronics housing,
  • Wide selection of materials.

Programmable output Linearization Function:
Output signal can be freely programmable. (Up to 14 compensated points at approximation).

Burnout current flexibility (Under Scale: 3.2 to 4.0 mA, Over Scale: 20.0 to 22.5 mA):
Burnout signal level is adjustable using Model FXW or Hand Held Communicator (HHC) to comply with NAMUR NE43.

Dry calibration without reference pressure:
Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration.

Technical specifications of GEORGIN FKE

  • Type : FKE : Smart, 4-20 mA DC + Georgin/Hart® digital signal
  • Service :
    Liquid, gas or vapour
  • Remark : To minimize environmental influence, span should be greater than 1/40 of the max. span in most applications.
  • Lower limit of static pressure (vacuum limit) : Silicone fill sensor : See Fig.1. Fluorinated fill sensor : 66 kPa abs (500 mmHg abs) at temperature below 60 °C. See fig.2
  • Overrange limit :To maximum static pressure limit.
  • Output signal : 4 to 20 mA DC with digital signal superimposed on the analogic signal.
  • Power supply : Transmitter operates on 10.5 V to 45 V DC at transmitter terminals. 10.5 V to 32 V DC for the units with optional arrester

Static pressure, span, and range limit :

Type Static
pressure
Span limit (mmH2O) Range limit
(mmH2O)
Minimum Maximum
FKE 02 Up to flange
rating
10 600  ± 600
FKE 03 32 3200  ± 3200
FKE 05 130 13000  ± 13000
FKE 06 500 50000  ± 50000
FKE 08 3000 300000  ± 300000

User Guide and Instruction manual for GEORGIN FKE

You can request the necessary certificates, documentation, instructions and user manuals for GEORGIN FKE using the special form.

You can buy GEORGIN FKE in UK or Europe at a favourable price in «DOLCHETRADE» by leaving a request on the website, by phone +441225535040 or by email . GEORGIN FKE price are subject to change depending on exchange rates. We deliver instruments by transport companies in the United Kingdom and Europe.