Sensor suitable for temperature measurement in district heating substations. Sensor with welded connector is applicable also for temperature measurement of liquid and gaseous media in high pressure conditions. Sensor consists of resistor placed in the thin-walled acid-resistant sheath connected to flexible lead protected with corrugated steel pipe.

  • flexible protection hose, stainless,
  • fiberglass insulation, metallic overbraid
  • material: stainless steel 1.4541
			
Warning: Undefined variable $term_list in /home/users/o/olil/domains/dolcetrade.com/wp-content/themes/olil2/template-parts/post/content-listing-with-gallery.php on line 76
int(8066) NULL

Made in Poland. brand LIMATHERM, model TTKWO-1

International delivery to Europe, Asia and Africa.
Our warehouses are located in the UK, UAE and Senegal.

price by request

Available

Available

Advantages

Only the best I&C brands

Our company is a global supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at very low prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Europe & Asia

We take care of all logistics and customs clearance of I&C solutions from Europe, USA, China and India

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Technical specifications of TTKWO-1

Measuring range / sensing element:

  • (-40 ÷ 400) ºC/ K / class 2

Sheath:

  • material: steel 1.4541
  • length L [mm]: 50÷1000
Thread dimension Max. Thermowell diameter d [mm]
M8x1 5
M10; M10x1; G⅛6 6
M12; M12x1,5; M12x1 8
G¼; M14x1,5 9
G⅜; M16x1,5 10
G½; M20x1,5 14

Lead wire:

  •  thermocouple wire: 2×0,22 mm2
  • fiberglass insulation with metal braid
  • measuring junction for TC: insulated SO
  • flexible protective hose, stainless ø7/ø5 mm
  • length Lp=1,5m (standard)

Options:

  • measuring junction for TC: grounded SP

Response time T05/T09

Sensor type ø9 ø11
K
insulated junction
≤22/≤62 ≤27/≤90
K
grounded junction
≤3/≤8 ≤6/≤15

Tolerance for thermocouples class acc to. PN-EN 60584

Thermocouple Class 1 Class 2
Range [°C] Tolerance [°C] Range [°C] Tolerance [°C]
K
NiCr-NiAl
(-40÷375)
(375÷1000)
±1,5
±0,004 |t|
from
(-40÷333)
(333÷1200)
±2,5
±0,0075 |t|

How to buy TTKWO-1

Ordering example:

  • TOPWO-1–200–Pt100–B–2–1,5m sensor with Pt100, class B, 2-wire connection connection, straight sheath ø5 mm without thread, sheath length L=200 mm, with lead wire – length Lp=1,5m
  • TOPWO-1–100–8–SO–1–G¼–2m sensor with thermocouple Fe-CuNi, class 1, insulated junction, sheath ø8 mm, with threaded connector G¼, lead wire length Lp= 2m

User Guide and Instruction manual for LIMATHERM TTKWO-1

You can request the necessary certificates, documentation, instructions and user manuals for LIMATHERM TTKWO-1 using the special form.

You can buy LIMATHERM TTKWO-1 in UK or Europe at a favourable price in «DOLCHETRADE» by leaving a request on the website, by phone +441225535040 or by email . LIMATHERM TTKWO-1 price are subject to change depending on exchange rates. We deliver instruments by transport companies in the United Kingdom and Europe.