+441225535040

Mon-Fri: 8:00 - 18:00 UK

Email:

TSI 3330 Optical Particle Sizer

An easy-to-use particle sizer with superior resolution and adjustable size channels

			
Warning: Undefined variable $term_list in /home/users/o/olil/domains/dolcetrade.com/wp-content/themes/olil2/template-parts/post/content-listing-with-gallery.php on line 76
int(17668) NULL

Made in USA. brand TSI, model 3330

International delivery to Europe, Asia and Africa.
Our warehouses are located in the UK, UAE and Senegal.

price by request

Available

Available

Advantages

Only the best I&C brands

Our company is a global supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at very low prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Europe & Asia

We take care of all logistics and customs clearance of I&C solutions from Europe, USA, China and India

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Descriptions of TSI 3330

The TSI Optical Particle Sizer (OPS) 3330 is a light, portable unit that provides fast and accurate measurement of particle concentration and particle size distribution using single particle counting technology. Backed by over 40 years of aerosol instrumentation design experience, the OPS uses state-of-the-art optics with 120° light collection and sophisticated electronics processing resulting in precision, high quality data. Rigorous factory calibration standards ensure measurement accuracy. The model 3330 can be used alone, or it can be placed in TSI’s weatherproof environmental enclosure

  • Features and Benefits
    ▪ Size resolution < 5% at 0.5 μm
    ▪ User adjustable size channels
    ▪ Size range: 0.3 – 10 μm in up to 16 channels
    ▪ Wide concentration range from 0 to 3,000 particles/cm3
    ▪ Color touch screen with intuitive user interface
    ▪ Fully compliant with ISO 21501-1
    ▪ Displays particle number concentration and particle mass with the ability to input refractive index and particle density
    ▪ Filter-based sample collection for later gravimetric or chemical analysis
    ▪ Battery-powered for up to 20 hours of operation
    ▪ Built-in data logging capability for up to 30,000 samples
    ▪ Temperature and pressure recorded for every sample
  • Applications
    Quality optical instruments are useful in a variety of applications due to their ease of use, fast measurement time, robustness, and reliability. A few common applications are listed below.
    ▪ Filter testing (i.e. ASHRAE 52.2)
    ▪ Indoor air quality
    ▪ Work place monitoring
    ▪ Outdoor environmental monitoring
    ▪ Industrial measurements
    ▪ Emissions monitoring and control

Technical specifications of TSI 3330

  1. Measurement Principle – 120° light scatter and filter sampling
  2. Particle Concentration Limit – Up to 3,000 particles/cm3 (3,000,000 particles/liter)
  3. Mass Concentration – 0.001 to 275, 000 μg/m3
  4. Particle Sizing
    Particle Size Range  – 0.3 to 10 μm
    Size Resolution  – 5% at 0.5 μm per ISO 21501-1
    Size Channels  – Up to 16, user-adjustablesize channels
  5. Sampling Time – ≥ 1 second, user-adjustable
  6. Zero Count – < 1 count per minute
  7. Flow Rate
    Sample  – 1.0 L/min; ±5% accuracy (meets ISO 21501)
    Sheath 1.0 L/min
  8. Environmental Conditions
    Operational Temp  – 0 to 45° C (32 to 113° F)
    Operational Humidity  – 0 to 96% RH, non-condensing
    Storage Temp –  -20 to 60° C (-4 to 140° F)
  9. Aerosol Medium – Air only
  10. Data Storage – 5MB on-board memory (30,000 samples)
  11. Communications
    Interfaces  – USB, Ethernet or USB flash drive
    Digital Display –  5.7 in. color touchscreen w/graphical display
    Analog Output  – 0 to 5V or 4 to 20 mA. User selectable out-put and user selectable
    Alarm Out – Visual indication, audible buzzer, relay or switch.
    User selectable set point
  12. Gravimetric Sampling – 37 mm filter inside standard removable 37mm filter cartridge
  13. Vacuum Source – Internal pump
  14. Light Source – Long lasting laser diode
  15. Power – AC Adaptor 100-240 VAC, 50/60 Hz, 15W
  16. Physical Features
    Physical Size (H x W x D)  – 13.5 x 21.6 x 22.4 cm (5.3 x 8.5 x 8.8 in.)
    Weight, Instrument  – 2.0 kg (4.4 lb)
    Weight, Battery – 0.5 kg (1 lb)
  17. Battery Performance (Hot Swappable)
    Runtime –  1 battery up to 10 hours, 2 batteries up to 20 hours
    Charge time – 1 battery up to 4 hours, 2 batteries up to 8 hours
  18. Software – Supplied with Aerosol Instrument Manager Software for the OPS
  19. Calibration – Annual calibration recommended at TSI using NIST* traceable materials and analytical tools
  20. Included Accessories – Operation manual, power supply, battery, purge filter, USB cable, carrying case and Aerosol Instrument Manager software for the OPS
  21. Optional Accessories – Additional battery, dual port external battery charger, aerosol diluters and environmental enclosure

User Guide and Instruction manual for TSI 3330

You can request the necessary certificates, documentation, instructions and user manuals for TSI 3330 using the special form.

You can buy TSI 3330 in UK or Europe at a favourable price in «DOLCHETRADE» by leaving a request on the website, by phone +441225535040 or by email . TSI 3330 price are subject to change depending on exchange rates. We deliver instruments by transport companies in the United Kingdom and Europe.