+441225535040

Mon-Fri: 8:00 - 18:00 UK

Email:

TSI 3082 Electrostatic Classifier

Used for aerosol classification and sizing in a broad variety of applications

			
Warning: Undefined variable $term_list in /home/users/o/olil/domains/dolcetrade.com/wp-content/themes/olil2/template-parts/post/content-listing-with-gallery.php on line 76
int(16733) NULL

Made in USA. brand TSI, model 3082

International delivery to Europe, Asia and Africa.
Our warehouses are located in the UK, UAE and Senegal.

price by request

Available

Available

Advantages

Only the best I&C brands

Our company is a global supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at very low prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Europe & Asia

We take care of all logistics and customs clearance of I&C solutions from Europe, USA, China and India

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Description of TSI 3082

Since 1976, TSI® Electrostatic Classifiers have been helping scientists generate and size submicrometer particles. These instruments have been used in a broad variety of research and have earned a well-deserved reputation for being highly reliable and extremely versatile. Our latest Electrostatic Classifier – the model 3082 – continues that tradition, but with expanded capabilities and an easy-to-use interface. The current design offers tool-free installation and auto detection of configurable components. The controller platform includes a touch-screen display and graphical user interface control that enables size distribution measurements with data logging, greatly expanding your research possibilities!

TSI’s Electrostatic Classifiers select highly monodisperse, submicrometer aerosols in the range from 1 to 1,000 nanometers in diameter. The Electrostatic Classifier is most often used as an integral part of a monodisperse aerosol generation system or in a submicrometer-particle sizing system.

Applications

The 3082 is a ‘primary standard’ instrument for aerosol measurement. This means that its performance is based on basic physical principles, and that results are highly repeatable.

The Classifier 3082 can be used for both aerosol generation and for aerosol size distribution measurement. The United States’ National Institute of Standards and Technology (NIST) uses a TSI® Long DMA for sizing 0.1-micrometer standard reference materials (Kinney et al, 1991).

Further detail on these two uses is provided on the next page. Because of these two capabilities, our Electrostatic Classifiers are suitable for a variety of applications:

When used as an aerosol generator to produce highly monodisperse particles:

  • Aerosol research, including the study of particle transport, diffusion, coagulation, nucleation, and condensation
  • Particle-charge and electrical-mobility studies
  • Filter media tests for filter efficiency
  • Calibration of particle instruments such as optical particle counters –enhancing the monodispersity of polystyrene latex (PSL) or other aerosols by removing residue particles and multiplets

When used in a TSI® SMPS™ spectrometer for high-resolution sizing of submicrometer particles:

  • Aerosol research, including the study of nucleation and condensation
  • Atmospheric monitoring and climate studies
  • Nanotechnology research and materials synthesis
  • Combustion and engine exhaust studies
  • Characterization of aerosols generated from flames, powders, sprays, or other sources

When monodisperse generation is used in tandem with size distribution measurement:

Measuring small and large changes in particle size due to coagulation, evaporation, condensation, humidification, and chemical reactions.

When used with a TSI® Aerosol Electrometer 3068B:

Primary size and concentration calibration of Condensation Particle Counters (ISO 27891) and other aerosol instruments.

Technical specifications of TSI 3082

for Electrostatic Classifier 3082 when combined with a selected DMA

3081A 3083 3085A 3086
General Capabilities Particle Type Solids and nonvolatile liquids
Particle Size Range
(generation mode)
Adjustable from
10 – 1000 nm
Adjustable from
2 to 150 nm
Adjustable from
1 to 50nm
Maximum Input Concentration* 107 particles/cm3
Voltage (DC) 10 to 10,000
Flow Rates Sheath Air (L/min) 2 to 30 2 to 20 2 to 30 2 to 25
Aerosol (L/min) 0.2 to 2 0.2 to 5 0.1 – 2.5
Physical Dimensions (DMA only) Height 61 cm (24 in.) 47 cm (18.5 in.) 20.3 cm (8 in.) 18.7 cm (7.4 in.)
Outside Diameter (excluding ports) 7.6 cm (3 in.) 13 cm (5.1 in.) 7.9 cm (3.1 in.)
Weight 5.5 kg (12 lb) 8.5 kg (18.7 lb) 2.2 kg (4.9 lb) 2.1 kg (4.6 lb)
Aerosol Port Diameters Polydisperse 1/4-in. OD 3/8-in. OD
Monodisperse 1/4-in. OD
Sheath, Excess Air 3/8-in. OD
Dimensions of Complete Instrument (3082 with DMA) Height 64.3 cm (25.4 in.) 52.8 cm (20.8 in.) 40.1 cm (15.8 in.)
Width 28.2 cm (11.1 in.) 40.5 cm (16 in.) 28.2 cm (11.1 in.)
Depth 40.5 cm (15.8 in.)
Weight 19.5 kg (43.0 lbs) 22.7 kg (50 lb) 16.4 kg (36.1 lb) 16.3 kg (36 kg)

*The input particle number concentration limit is imposed by the neutralizer that precedes the DMA.

User Guide and Instruction manual for TSI 3082

You can request the necessary certificates, documentation, instructions and user manuals for TSI 3082 using the special form.

You can buy TSI 3082 in UK or Europe at a favourable price in «DOLCHETRADE» by leaving a request on the website, by phone +441225535040 or by email . TSI 3082 price are subject to change depending on exchange rates. We deliver instruments by transport companies in the United Kingdom and Europe.