  • Industry-leading speed & response: T90 ≤ 3 seconds even with splash guard installed
  • No routine calibration required reducing maintenance costs
  • Industry standard 4-20 mA output provides remote alarm and fault indication
  • Multiple communication outputs provide complete status and control capability in the control room
  • Heated optics eliminate condensation
  • Dirty optics indication discriminates between true fault and cleaning requirements
  • Fast calibration times reduce amount of cal gas required which lowers maintenance time and costs
			
Warning: Undefined variable $term_list in /home/users/o/olil/domains/dolcetrade.com/wp-content/themes/olil2/template-parts/post/content-listing-with-gallery.php on line 76
int(17061) NULL

Made in USA. brand MSA Safety, model IR400

International delivery to Europe, Asia and Africa.
Our warehouses are located in the UK, UAE and Senegal.

price by request

Available

Available

Advantages

Only the best I&C brands

Our company is a global supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at very low prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Europe & Asia

We take care of all logistics and customs clearance of I&C solutions from Europe, USA, China and India

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Descriptions of MSA IR400

  • Model IR400 infrared (IR) point detector is a microprocessor-based combustible gas detector that continuously monitors combustible gases in the lower explosive limit (LEL) range and provides a 4 to 20 mA analog signal proportional to the 0 to 100% LEL concentration. The detector also monitors other conditions such as supply voltage and optical path integrity.
  • The IR400 detection principle is based on measuring absorption of infrared radiation passing through a volume of gas using a dual beam, single detector method. IR detector measures the intensity of two specific wavelengths, one at an absorption wavelength and another outside of the absorption wavelength. The gas concentration is determined by a comparison of these two values.
  • Most industrial point IR gas detection applications require a splash guard to protect the
    sensing element from rain and other environmental conditions. In many cases, the addition of a splash guard slows the speed of response considerably and should be taken into consideration.
  • The IR400 gas detector responds within three seconds to gas leaks even with a splash guard installed.
  • Configurations with analog output, Modbus, and HART are available. IR400 provides a twowire
    RS-485 addressable communications link conforming to Modbus protocol that is used to
    monitor the IR400’s status and settings in order to simplify installation and maintenance. Data
    available through HART or Modbus, such as configuration device settings and stored maintenance records, can be used to perform diagnostics and take corrective action before a
    problem occurs.
  • The IR400 is calibrated at the factory and needs no routine field calibration. It requires only a
    periodic cleaning of the windows and re-zeroing to ensure dependable performance

Applications

  • Chemical plants
  • Compressor stations
  • Drilling and production platforms
  • Fuel loading facilities
  • Oil well logging
  • LNG/LPG processing and storage facilities
  • Refineries
  • Wastewater treatment facilities

Technical specifications MSA IR400

System Specifications
Detector Type Infrared absorption type
Measuring Range  0 to 100% LEL
0 to 100% by volume (methane only)
Gases Methane, propane, ethane, ethylene, butane,
hexane, pentane
Consult factory for other gases
Detector Life  greater than 5 years
Accuracy
@ 25°C
± 3% LEL at ≤ 50% LEL reading
± 5% LEL at > 50% LEL reading
Zero drift
 
< 2% per year
Response time 
With Splash Guard
T50 ≤ 1.5 s, T60 ≤ 1.5 s, T90 ≤ 3 s

Except ethylene where T60 ≤ 2 s and T90 ≤ 4 s

Readout / Relay
Display modules
DC110; TA102A; IR4000 display, and relay alarms
Accessories Junction box, duct mount junction box,calibration cup, flow block, splash guard,
rain guard, portable purge calibrator
Classification  Class I, Zone 1, IIB + H2
(Ta=-40° C to +75° C)
Ex d, IIB + H2 T5 gb
Ex tb IIIC, T100° C Db, IP66
(Ta=-60° C to +75° C)
Warranty Two years
Approvals ATEx, IECEx, MED, DNV gL, CE,
FM 6310, 6320 and CSA 22.2 No. 152
EN 60079-29-1 Performance Approved
HART Registered, SIL 3 suitable
FM Certified to IEC 61508

Environmental Specifications

Operating temperature range
FM, CSA, GOST-R
ATEx, IECEx
ETHYLENE
-40° F to +167° F (-40° C to +75° C)
-76° F to +167° F (-60° C to +75° C)
-40° F to +140° F (-40° C to +60° C)
Storage temperature range
-58° F to +185° F (-50° C to +85° C)
Oparating humidity range
10% to 95% RH, non-condensing
Electrical Specifications
Input power
20-36 VDC @ 200 mA max.
24 VDC nominal
Analog signal
START UP, FAULT (non-HART)
START UP, FAULT (HART)*
CAL, ZERO, GAS CHECk*
DIRTy OPTICS*
0 TO 100% LEL
OVER-RANGE
0-21.7 mA (600 ohms max.)
0 mA
1.25 mA
1.5 mA
2.0 mA
4 to 20 mA (proportional)
20 to 21.7 mA
EMC
Complies with EN 50270, EN 61000-6-4
Cable requirements
Max. distance between IR400 and
power source @ 24 VDC nominal
(20 ohm loop resistance):
14 AWg (2.0 mm2) – 3600 ft (1100 m)
Max. distance for analog output (500 ohms max):
14 AWg (2.0 mm2) – 9000 ft. (2740 m)
Faults monitored
Re-calibration error, EPROM checksum error, optics failure/blockage; low supply voltage, EEPROM checksum error, reference or active lamp failure, heater failure, time to re-zero unit, short circuit on CAL_IO wire
RS-485 output
 Modbus RTU, suitable for linking up to 128 units
or up to 247 units with repeaters
Baud rate
2400, 4800, 9600, or 19200 BPS
Hart (optional)

 

HART 6, HART Device Descriptor available.
AMS aware
Wireless communication
Available with ELPRO Technologies
wireless devices

Mechanical Specifications

Diameter
2.9” (74 mm)
Length
8.87” (225 mm)
Weight
ALUMINUM
STAINLESS STEEL
3 lbs (1.35 kg)
6 Ibs (2.7 kg)
Mounting  ¾” NPT
Ingress protection
Type 4x, IP66
Housing
Aluminum 6061-T6 alloy or
316 stainless steel
Standard configuration
IR400-0-01-1-2-0-1-0
Methane, 4-20 mA, Modbus, aluminum,
splashguard w/screen, no junction box

User Guide and Instruction manual for MSA Safety IR400

You can request the necessary certificates, documentation, instructions and user manuals for MSA Safety IR400 using the special form.

You can buy MSA Safety IR400 in UK or Europe at a favourable price in «DOLCHETRADE» by leaving a request on the website, by phone +441225535040 or by email . MSA Safety IR400 price are subject to change depending on exchange rates. We deliver instruments by transport companies in the United Kingdom and Europe.