+441225535040

Mon-Fri: 8:00 - 18:00 UK

Email:

DDTOP MTF Variable Area Flow Meter (Rotameter)

MTF variable area flow meter is measured by outputting 4~20 mA two-wire linear current signal, and the communication protocol is loaded. The remote configuration, monitoring, maintenance and calibration of the instrument can be realized. The pressure regulator (constant flow valve) can be selected to make the outlet flow stable.

			
Warning: Undefined variable $term_list in /home/users/o/olil/domains/dolcetrade.com/wp-content/themes/olil2/template-parts/post/content-listing-with-gallery.php on line 76
int(9776) NULL

Made in China. brand DDTOP, model MTF

International delivery to Europe, Asia and Africa.
Our warehouses are located in the UK, UAE and Senegal.

price by request

Available

Available

Advantages

Only the best I&C brands

Our company is a global supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at very low prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Europe & Asia

We take care of all logistics and customs clearance of I&C solutions from Europe, USA, China and India

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Description of DDTOP MTF

MTF Variable Area Flow Meter is an intelligent instrument developed by our company. It converts the fluid flow signal into corresponding analog voltage signal, outputs 4~20mA two-wire linear current signal and loads HART protocol for communication. With the features of high precision, low drift, and strong anti-interference ability, it can realize the remote configuration, monitoring, maintenance and calibration of the instrument and the flow measurement, supervision and management of the production process.

Operating Principle
The measured fluid flows in from the lower end of the measuring tube, and with the action of the fluid, a differential pressure is generated between the upper and lower ends of the float, and this differential pressure is the lifting force of the float. The float will remain in a certain position when the lifting force applied to the float is balanced with the gravity of the float. The measured flow rate corresponds to the position of the float in the measuring tube, as shown in Figure 1. through the float’s built-in magnet coupled with the detection of the magnetic steel on the axis of the indicator, the flow rate is displayed directly on the dial, or through the circuit conversion, the Hall sensor transforms the magnetic signal into electrical signal, and then processed by the controller, the flow rate is displayed on the LCD screen, 4-20mA current signal is output, loading a digital signal compliant with the HART protocol communication.

Features

1.It can measure liquid, gas and vapor, especially for the flow measurement with small flow rate and low Reynolds number, it has more unique advantages than other flow meters.
2.Lower pressure loss, generally is 4~9kpa, higher is 20kpa.
3.There is a wide flow range, generally is 10:1, the special design flow range can be extended.
4.The factory calibration adopts the method of 11 sections calibration, and the precision of the product reaches 1.0 grade.
5.It can select card sleeve connection, piping φ6mm、φ8mm、φ10mm、φ12mm. Flange connections can also be selected and the flange standard is determined according to user requirements.
6.Max pressure is 69Mpa

Technical specifications of DDTOP MTF

1. Main parameters

  • Power Supply: 12V~30VDC
  • Output signal:Two wire, 4~20mADC + HART
  • Flange standard:HG/T20592; HG/T20615 (or on request)
  • Power entrance:M20×1.5(F) or on request
  • Input impedance:>100MΩ
  • Standard load resistance:250Ω
  • Nominal pressure:DN15~DN50: PN≤0MPa;DN80~DN100: PN≤6.3MPa (or on request)
  • Accuracy:0% FS, 1.5% FS, 2.0% FS
  • Range ratio: 10:1
  • Fluid temperature: -40℃≤T≤300℃
  • Damping period: (0~16 seconds)
  • Ambient temperature:-40℃≤T≤80℃(When ≤ -35℃, LCD cannot display)
  • Explosion proof type: Intrinsically safe explosion type Exia Ⅱ C T5/T4 Ga, Isolation explosion type Exd Ⅱ C T6/T5/T4/T3 Gb
  • IP Rating:IP66
  • Measuring Range

Water:2.5 L/h~100000L/h(20℃)

Air:0.07~1800m3/h(0.1013MPa, 20℃)

  • Medium temperature:350℃≤T≤450℃
  • Applicable Fluid viscosity

DN15, DN20:η<5mPa.s(FZ15.1~FZ15.5)

η<30mPa.s(FZ15.6,FZ15.15,FZ20.1~FZ20.4)

DN25, DN40: η<250mPa.s

DN50, DN80, DN100: η<300mPa.s

2. Classification

  • Classification by mounting type: vertical installation and horizontal installation
  • Classification by applicable fluid

Basic type: apply to liquid measurement

Damping type: apply to gas and vapor measurement

Anti-corrosion type: lining with PTFE and apply to corrosive fluid measurement      Jacket type: apply to the fluid needs to keep warm or cold.

Notice: There is no horizontal installation for anti-corrosion type or jacket type

 How to buy DDTOP MTF

Model Code Content
MTF – A Pointer indicating type   variable area flow meter
B Digital display + remote transmission type   variable area flow meter
C Pointer indicating + remote transmission type  variable area flow meter
D Pointer indicating + digital display + remote transmission type variable area flow meter
2 PN10(1.0MPa)
3 PN16(1.6MPa)
4 PN20(Class150)
5 PN25(2.5Mpa)
6 PN40(4.0MPa)
7 PN50(Class300)
8 PN63(6.3Mpa)
9 PN100(10.0Mpa)
10 PN110(Class600)
…… Other nominal pressures shall follow the actual code of sage X3 system
Z Damping type
W Non damping type
2 11      DN15          1/2″
3 12      DN20          3/4″
4 13      DN25           1″
6 15      DN40           1-1/2″
7 16      DN50            2″
9 18      DN80            3″
10 19       DN100            4″
/
P Wetted Material: lining with PTFE
2 Wetted Material: 304
3 Wetted Material: 316
4 Wetted Material: 316L
…… Other material shall follow the actual code of sage X3 system
0 NA
i Intrinsically safe
d Explosion isolating
D Fluid Temperature: 0℃<T≤200℃
G Fluid Temperature: -40℃≤T≤0℃ 200℃<T≤300℃
S Horizontal Installation
C Vertical Installation
MTF – /

Example

MTF-B3W4/2dDC is Variable Area Flow Meter: Digital display + remote transmission type; Flange rate is PN1.6, Non damping type, Size DN25, Wetted material is 304, Isolation explosion type , Working temperature is 0℃<t≤200℃, Vertical installation.

Model selection flow table

Nominal Diameter Connectable Flange Float

Number

Flow valueWater L/h; Air m3/h Pressure Loss (kPa)
Water Calibration Air Calibration Water Calibration Air Calibration
Float material Float material
304 PTFE 304 304 PTFE 304
DN15 ≥DN15 FZ15.1 25 0.7 6.5 7.1
FZ15.2 32 25 1 6.5 5.5 7.1
FZ15.3 40 40 1.2 6.5 5.5 7.2
FZ15.4 50 60 1.5 6.5 5.6 7.2
FZ15.5 60 100 1.8 6.6 5.6 7.3
FZ15.6 80 160 2.5 6.6 5.8 7.4
FZ15.7 100 250 3 6.6 6.1 7.5
FZ15.8 130 400 4 6.7 7.3 7.8
FZ15.9 160 4.9 6.8 8.0
FZ15.10 200 6.2 7.0 8.9
FZ15.11 250 7.7 7.2 10.0
FZ15.12 320 9.9 7.9 10.4
FZ15.13 400 12.3 8.6 10.8
FZ15.14 500 15.4 9.9 12.4
FZ15.15 600 18.5 11.1 14.0
DN20 ≥DN20 FZ20.1 750 23 6.9 5.9 7.3
FZ20.2 1000 30 7.1 6.2 7.5
FZ20.3 1300 40 7.5 7.9
FZ20.4 1600 49 7.8 8.2
FZ20.5 2000   62 7.8 8.2
DN25 ≥DN25 FZ25.1 1000 600 30 7.0 5.5 7.7
FZ25.2 1300 1000 40 7.5 5.6 8.3
FZ25.3 1600 1600 49 8.0 5.6 8.8
FZ25.4 1800 2500 55.5 8.6 6.4 9.5
FZ25.5 2100 65 9.5 10.5
FZ25.6 2300 71 10.1 11.2
FZ25.7 2500 77 10.8 12.0
FZ25.8 2900 90 13.2 13.2
FZ25.9 3200 100 14.2 14.1
FZ25.10 3600 111 15.6 15.3
FZ25.11 4000 123 16 16.5
FZ25.12 4400 135 17.4 17.8
FZ25.13 4800 148 18.8 19.0
DN40 ≥DN40 FZ40.1 3000 93 7.2 6.2 7.8
FZ40.2 3750 116 7.4 6.5 8.2
FZ40.3 4500 139 7.5 7.1 8.5
FZ40.4 5500 170 7.9 8.5 9.0
FZ40.5 6500 200 8.3 9.4
FZ40.6 7500 230 9.1 9.9
FZ40.7 8500 262 9.8 10.3
FZ40.8 10000 309 10.0 10.7
Nominal Diameter Connectable Flange Float

Number

Flow valueWater L/h; Air m3/h Pressure Loss (kPa)
Water Calibration Air Calibration Water Calibration Air Calibration
Float material Float material
304 PTFE 304 304 PTFE 304
DN50 ≥DN50 FZ50.1 6000 4000 185 8.1 6.8 8.6
FZ50.2 7000 6000 220 8.8 8.8 9.1
FZ50.3 8000 10000 250 9.5 13.7 9.6
FZ50.4 10000 14000 310 11.0 18.5 10.4
FZ50.5 13000 400 14.0 12.9
FZ50.6 16000 495 17.0 15.5
FZ50.7 20000 620 19.7 16.4
FZ50.8 25000 770 20.0 18.6
DN80 ≥DN80 FZ80.1 25000 16000 770 8.1 6.3 8.0
FZ80.2 30000 25000 925 8.6 7.2 10.0
FZ80.3 35000 1080 9.1 12.0
FZ80.4 40000 1234 9.5 14.0
DN100 ≥DN100 FZ100.1 60000 35000 1800 10.0 7.9 25.0
FZ100.2 100000 15.0

User Guide and Instruction manual for DDTOP MTF

You can request the necessary certificates, documentation, instructions and user manuals for DDTOP MTF using the special form.

You can buy DDTOP MTF in UK or Europe at a favourable price in «DOLCHETRADE» by leaving a request on the website, by phone +441225535040 or by email . DDTOP MTF price are subject to change depending on exchange rates. We deliver instruments by transport companies in the United Kingdom and Europe.

See also: Flow meters