+441225535040

Mon-Fri: 8:00 - 18:00 UK

Email:

DDTOP LGY Compact Orifice Plate Flow Meter

LGY compact orifice plate flow meter is composed of flow element, differential pressure transmitter, three-way manifold, temperature sensor and pressure sensor, which can measure liquid, gas, vapor and other medium.

			
Warning: Undefined variable $term_list in /home/users/o/olil/domains/dolcetrade.com/wp-content/themes/olil2/template-parts/post/content-listing-with-gallery.php on line 76
int(9899) NULL

Made in China. brand DDTOP, model LGY Compact

International delivery to Europe, Asia and Africa.
Our warehouses are located in the UK, UAE and Senegal.

price by request

Available

Available

Advantages

Only the best I&C brands

Our company is a global supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at very low prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Europe & Asia

We take care of all logistics and customs clearance of I&C solutions from Europe, USA, China and India

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Description of DDTOP LGY Compact

LGY compact orifice plate flow meter consists of a flow element, a differential pressure transmitter, a manifold, a temperature sensor and a pressure sensor, and can measure various medium such as liquid, gas, and vapor. The flow element implements the standard of GB/T2624-93 “Flow Measurement Flow Element Uses Orifice Plate, Nozzle and Venturi Tube to Measure the Flow of Fluid Filled with Circular Pipe” , adopting LG-94-01win “Flow Element Design Calculation And Management Software”design calculation, according to JJG640-1994 “Differential Pressure Flow meter Verification Regulations” and JB4730-94 “Pressure Vessel Non-destructive Test”, and verify the actual measurement accuracy through the flow standard device inspection.

Structure Type
LGY compact orifice plate flow meter has two main structure forms: one is simple integration, which is to assemble the orifice plate, manifold, and differential transmitter together. This structure is used in situations where temperature and pressure are relatively stable; the other is compensation integration. It is to assemble the orifice plate, the manifold, and the differential transmitter together, and increase the temperature and pressure compensation function. This product has high measurement accuracy and is suitable for occasions that require precise measurement.
LGY compact orifice plate flow meter has compact structure and simple installation, which can save a lot of installation work for users; assembled in the factory to ensure stable and consistent measurement accuracy, the consumption of LGY compact orifice plate flow meter has increased significantly in recent years, and the common specifications are concentrated below DN150.

Features

1.LGY compact orifice plate flow meter has advantages of compact structure, simple installation and can save a lot of installation working time.

2.All products are assembled in the factory to ensure accuracy stable and consistent.

3.LGY compact orifice plate flow meter use imported differential pressure transmitter, the flow element implements the national standards and the actual measurement accuracy is determined by the standard flow inspection device.

4.LGY compact orifice plate flow meter has temperature and pressure compensation algorithm to improve the measurement accuracy.

Applications

Refining: Coking, Hydrogenation Desulfurization, Sulfur Recovery, Distillation Tower, Catalytic Stripping Tower.

Technical specifications of DDTOP LGY Compact

  • Technical Parameters and Performance
  • Nominal Diameter: 50~600 mm, Special Design:15~50, 600~1000mm,
  • Nominal Pressure:0MPa
  • Medium Temperature: 150℃,450℃(Only limited to separated type)
  • Output:4~20mA ,4~20mA+HART
  • Range Ratio: 10:1
  • Accuracy: ±1% (Measurement Accuracy)
  • Explosion Proof Type:Intrinsic Safe: iaⅡCT6; Explosion proof: dⅡBT4
  • IP Rating:IP66

 How to buy DDTOP LGY Compact

Serial Number Code Content
LGY Compact Orifice Plate Flow Meter
A Corner Tap
B Flange Tap
C Other
026 DN25
04 DN40
05 DN50
08 DN80
10 DN100
60 DN600
01 PN16
02 Class150
03 PN25
04 PN40
05 Class300
06 PN63
10 PN100
11 CL600
15 CL900
16 PN160
26 Class1500
42 Class2500
A With Differential Transmitter
B With Differential Transmitter and Flow Totalizer
C With Temperature And Pressure Compensation Differential Pressure Transmitter
D Other

User Guide and Instruction manual for DDTOP LGY Compact

You can request the necessary certificates, documentation, instructions and user manuals for DDTOP LGY Compact using the special form.

You can buy DDTOP LGY Compact in UK or Europe at a favourable price in «DOLCHETRADE» by leaving a request on the website, by phone +441225535040 or by email . DDTOP LGY Compact price are subject to change depending on exchange rates. We deliver instruments by transport companies in the United Kingdom and Europe.