+441225535040

Mon-Fri: 8:00 - 18:00 UK

Email:

Advantages

Only the best I&C brands

Our company is a global supplier of control and measuring instruments from well-known world brands

Advantages

Discounts for organisations

We sell high-tech equipment at very low prices. We provide really advantageous conditions for partners

Advantages

Fast delivery across the Europe & Asia

We take care of all logistics and customs clearance of I&C solutions from Europe, USA, China and India

Advantages

Professional advice on device selection

Our specialists are ready to advise you on any technical question. We can find an analogue of any device

Device selection filter

Device selection filter

Explosion proof temperature sensors Exd

Our company offers you to buy Explosion proof temperature sensors Exd at excellent prices. Leave a request on the website and our specialists will send you a quotation within 1-2 days.

Products not found

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • process connection with G1/2 or M20x1,5 thread
  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541 flange PN16, DN20, DN25
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • process connection with G1/2 or M20x1,5 thread
  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541 flange PN16, DN20, DN25
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • process connection with G1/2 or M20x1,5 thread
  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68,cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • process connection with G1/2 or M20x1,5, 1/2NPT thread
  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

Db IP66

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • process connection with G1/2 or M20x1,5, 1/2NPT thread
  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • process connection with G1/2 or M20x1,5, 1/2NPT thread
  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

Db IP66

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • process connection with G1/2 or M20x1,5, 1/2NPT thread
  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • process connection with G1/2 or M20x1,5, 1/2NPT thread
  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

Db IP66

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • process connection with G1/2 or M20x1,5, 1/2NPT thread
  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541, 1.4571, 2.4816
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ext IIIC T85ºC Db IP66

  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541, 1.4841, 1.4762
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68,cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

 

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541, 1.4571, 2.4816
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ext IIIC T85ºC Db IP66

  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541, 1.4841, 1.4762
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68,cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

 

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ext IIIC T85ºC Db IP66

  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541, 1.4841, 1.4762
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68,cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

 

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • process connection with G1/2 or M20x1,5, 1/2NPT thread
  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541, flange PN16, DN20. DN25
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • process connection with G1/2 or M20x1,5, 1/2NPT thread
  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541, flange PN16, DN20. DN25
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • process connection with G1/2 or M20x1,5, 1/2NPT thread
  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541, flange PN16, DN20. DN25
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541 or 1.7335
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541 or 1.7335
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541 or 1.7335
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541 flange PN16, DN20, DN25
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX

price by request

Read more
Available

Available